On this page you find the DeLonghi Tasciugo AriaDry Compact DDS 25 manual. Please read the instructions in this operator manual carefully before using the product. If you have any questions about your that are not answered in the manual, please share your question in the troubleshooting section on the buttom of this page.
IMPORTANT INFORMATIONWhen using electrical appliances, basic safety precautions should always be followed, including the following:- Read all instructions.- To protect against fire, electrical shock and personal injury, do not immerse cord, plug or appliance in water or other liquid.- Close supervision is necessary when any appliance is used by or near children.- Do not operate with a damaged cord or plug, or after the appliance malfunctions, or has been damaged in any manner. Return the appliance to the nearest authorized service facility for examination, repair or adjustment.- The use of accessory attachments or spare parts not recommended by the appliance manufacturer may result in fire, electrical shock or personal injury.- Do not use outdoors.- Do not use the appliance for other than the intended use.- Do not place any strain on the power cord.
Dear user,We thank you for purchasing the Pinguino air-conditionerand congratulate you on your wise choice.For optimal results please read this manual carefully before installing or operating.We know that the Pinguino will maintain your environment pleasingly comfortable at all times.With best wishesDeLonghi America, Inc.If you have any questions about the operation or service of your Pinguino, please call our toll-freeservice number 1-800-322-3848or1 - 877-235-1052in the U.S. (905) 2381313 in Canada. SPECIFICATIONSPower supply voltageV110-120FrequencyHz60Cooling capacity:With waterBtu8500.With airBtu7500.Current consumptionA/W6,5/ 990Water tank capacitypints30.65Air flow capacitycfm.212Room thermostat(34° to 102°F)adjustableDimensions:widthin.22”,05heightin.28”,74depthin.15”,35Net weightlbs.97Refrigerant system(freon)R 22Compressor protectionOverload relayFreon chargelb. (gr)see rating label.Data according to pending standard testing procedures subject to review by the U.S. Of Energy.OPTIMUM OPERATING RANGEROOM TEMPERATURE70°F - 90°FROOM HUMIDITY FACTOR50% - 80% RHPOWERFREQUENCY60 HZSUPPLYVOLTAGE115V.
PERMANENT INSTALLATIONThe Pinguino accessories include one wall vent for exhausting your Pinguino. Once installed, this vent is the only item needed for using Pinguino.fig.
1Permanent installation outlet holes must be in an exterior wall and opening diameter should not exceed 4” 1/ 2.INSIDEOUTSIDEINSIDEOUTSIDE4”.174”.17fig. 3A2in a window panethrough the wooden base-section of a door or windowINSIDEOUTSIDE1”In case of fixed installation, air discharged”4.17from rear hose has been extracted from theroom where the appliance is installed.Check that the room (especially if small) isnot “air-tight”;a drop in pressure wouldcause irregular functioning, which couldconsequently activate reset switch. AirA3entering through door and window cracksis normally sufficient. If deemed, necessaryfig. 4through the wallleave a door ajar (approx. 1/2 inch isenough). Pinguino is equipped with an adjustable window bracket.
If you have a sash window, place the bracket on the window sill, extend the bracket fully within the window frame and lower the window onto the bracket. Insert the nozzle of the exhaust hose into the slot, then connect the hose to the air conditioner (Fig. 7).Thanks to the wing nut, it’s possible to use the window bracket also for sliding windows. Position the hole of the bracket so to allow a correct installation of the exhaust hose (see the following instructions).window bracketfig. 1) Water collects at this point2) Bend this section3) Bend this sectionfig.
8 NO YES YESELECTRICAL CONNECTIONCheck that the power supply voltage is 115 V 60 Hz.Important: if you need to use and extension cord, please be sure touse a heavy duty extension cord (minimum 14 gauge). Before connecting the Pinguino to power supply, make sure that all switches on the front control panel are in the OFF position.Connect power cord found in storage compartment at rear of thefig. 9Pinguino (Fig. SPECIAL NOTEThis machine is designed to be used with or without water.
Maximum performance is obtained using water. When used without water, Pinguino will maintain a full 88% of its cooling capacity.HOW TO PREPARE WATER CONTAINERUse only clean, salt-freetap water.
The water is essential for the air cooling operation and si discharged in the form of steam through the exhaust outlet. A container full of water lasts for a period that depends on a number of conditions such as temperature, humidity, insulation, exposure of the room, number of people present, etc. On average it will last approximately 7 to 10 hours.When the container is empty, the appliance automatically changes function from water to air. At the same time, the quantity of air discharged from the rear hose will increase. N.B: For technical reasons, the temperature is not expressed in degrees but by a line increasing in thickness. We therefore recommend that when starting up the appliance, the thermostat be turned to maximum (thick green line = maximum cold).
When the desired temperature has been reached, turn the thermostat slowly away from the maximum cooling position until the appliance switches off. Cricket 07 roster 2017 download hd. Leave the thermostat in this position. The air-conditioneris now programmed to maintain the exact temperature at all times.After switching the appliance off, wait at least 3 min.
Before switching on again. HOW TO START UP THE CONDITIONER (see control panel on the previous page)Plug the appliance into the wall socket.Select the “programmed” or “non programmed” mode (see previous page)Select the fan speed required pressing “Fan speed” key C.AIR-CONDITIONINGKey A ON/OFF ( conditioning) must be released Turn the thermostat to Max. Cold.Press key A ( ON/OFF).ON/OFF signal lamp ( conditioning) will come on.The appliance comes on.If not, refer to pag. 14.To switch off the appliance, press key A (ON/OFF main switch). AIR FILTER CLEANINGMaintenance of air filterRemoval and replacement of air filterA clogged air filter reduces the quantity ofGently pull filter upwards.circulating air and the efficiency of thePush down to replace.appliance.
Clean filter every week using avacuum cleaner.fig. 23Remove dust with aRinse with runningvacuum cleanerwaterfig. 24Cleaning procedureTo remove dust deposited on filter, use a vacuum cleaner. If it is very dirty, soak in lukewarm water and rinse thoroughly. The temperature of the water must be kept below 104°F. After washing, leave filter to dry before replacing.END OF SEASON OPERATIONS5) Remove exhaust hose.6) Clean filter and dry well before replacing.7) Cover appliance with a polyethylene bag to prevent dust from entering.You can use the polyethylene bag included into the packaging.fig. 251) Disconnect plug.2) Remove tank and empty it.3)Some water may remain into the tank.
26avoid unpleasant odors, pour two spoons ofbleach into the tank.4)Drain water from collecting tray. PERIODIC MAINTENANCECalcium deposits may build up on some working parts of Pinguino during operation. Monthly cleaning (more often in hard water areas) should be done per the following procedure:- Unplug the machine. Remove the water tank. Run the air-conditioneruntil water level indicator light turns on.- Remove drainage tube plug and empty water.
Replace drainage tube plug and add one quart of clean water to the collecting tray.- Empty contents of one 8-ouncebottle of Descaling Fluid into the collecting tray. Plug in the machine and operate until water level indicator light goes on. Turn off and unplug machine.- Drain the remaining liquid and re-plugthe drainage tube.- Refill the tank with clean water and replace in the machine.- Plug in and turn on the machine. While the air-conditioneris operating, unplug the drainage tube and drain until the water looks clean. Replace the drainage tube plug.TROUBLESHOOTINGSYMPTOMSCAUSESOLUTIONThe Pinguino does not-power failurefunction:-plug is disconnected-insert plug- ON/OFF switch is off-switch on- Timer key is in STOP position- release the TIMER keyThe Pinguino does notfunction-exhaust hose blocked- Check for obstruction of air- function fault warninglight is on (pag.
10 -outlet vent“Alarm” light)-exhaust hose twisted or bent-eliminate irregularitiesAfter correcting problem,- ventilation holes on the rear of- remove obstacles to allowthe machine or front louversproper airflowpress reset button (seeblockedpag. 5)The Pinguino produces-window open-close windowcold air but room does-air exhaust hose has become-re-insertexhaust hosenot maintain comfortabledisconnectedtemperature:-thermostat set too low-set thermostat to highernumber-air filter blocked-clean filter-water tank empty-refill itSERVICINGIn case of malfunction turn off and disconnect the Pinguino from power outlet and contact our Service Centre for qualified assistance, toll-freenumber 1-800-322-3848or 1 - 877-235-1052in America or no. (905) 238-1313for Canada. FOR UNITED STATES ONLY:LIMITED WARRANTYWe warrant each DELONGHI AIR-CONDITIONERto be free from defects in material and workmanship. Our obligation under this warranty is to provide one year parts and labor free from purchase date, with an additional four (4) years on any part of the sealed system consisting of the compressor, evaporator, condenser and factory connected refrigerant tubing.
This warranty shall apply only if the AIR-CONDITIONERis used in accordance with the factory directions which accompany it, and on Alternating Current (AC) circuit. This warranty is in lieu of all other warranties and representations, expressed or implied, and all other obligations or liabilities on our part. We do not authorize any other person or company to assume for us any liability in connection with the sale or use of our AIRCONDITIONER. This warranty shall not apply to assume for us any liability in connection with the sale or use of our AIR-CONDITIONER.This warranty shall not apply to any AIRCONDITIONER which shall have been repaired or altered outside our factory nor shall it apply to any AIR-CONDITIONERwhich has been subjected to misuse, negligence or accidents.If repairs become necessary or spare parts are needed, please write to:DELONGHI America Inc.Park 80 West Plaza One, 4th floorSaddle Brook NJ 07663or call Service Tel. No 1-800-322-3848.